Question 1 · Complete heart block on ECG
Correct answer: Complete (third degree) heart block — P waves and QRS complexes completely dissociated. Ventricular escape rhythm (usually wide complex)
Why
Complete (3rd degree) heart block: complete AV conduction failure. P waves fire independently (SA node rate). QRS complexes are escape rhythm (junctional 40-60 bpm/narrow, or ventricular 20-40 bpm/wide). No P-QRS relationship. Most dangerous bradyarrhythmia — can cause syncope, heart failure, arrest. Ventricular escape <40 bpm or wide = unstable.
Key point
3rd degree block: independent P waves + escape QRS, no relationship. Ventricular escape wide/slow = unstable. Emergency pacing.
Question 2 · Causes of CHB
Correct answer: Inferior STEMI (RCA → AV node), Lyme disease, drug toxicity (digoxin, β-blocker, CCB overdose), hyperkalaemia, acute myocarditis
Why
CHB acute causes: Inferior MI (RCA supplies AV node) — usually transient. Drug toxicity: digoxin, β-blockers, diltiazem, verapamil — check levels. Hyperkalaemia: can cause all degrees of block. Lyme disease: 3rd degree block in endemic areas. Acute myocarditis. Structural: fibrosis (Lev's disease), sarcoidosis, infiltrative disease. Congenital CHB: anti-Ro/La antibodies (maternal SLE).
Key point
CHB: exclude inferior MI (ECG), drug toxicity, hyperkalaemia, Lyme, myocarditis. Inferior MI CHB often transient.
Question 3 · Transcutaneous pacing
Correct answer: Electrical capture: pacer spike followed by wide QRS (not just the pacer artefact). Mechanical capture: palpable pulse with each paced beat. Check pulse not just the monitor
Why
TCP capture verification: ECG: broad QRS after each pacing spike = electrical capture. Must also confirm MECHANICAL capture: palpate femoral/brachial pulse with each paced beat (radial can be confused with muscle artefact from pacing). SpO2 waveform can help. TCP is painful — analgesia and sedation. Transvenous pacing is more reliable if TCP fails.
Key point
TCP: verify electrical capture (spike + wide QRS) AND mechanical capture (palpable pulse). TCP painful — give sedation/analgesia.
Question 4 · Transvenous pacing
Correct answer: Internal jugular or subclavian approach preferred — fluoroscopy-guided positioning of pacing wire in RV apex. Complications: pneumothorax (subclavian), line infection, cardiac perforation
Why
TVP: central venous access (IJ or subclavian preferred, femoral less stable). Fluoroscopy-guided RV apex pacing. Complications: pneumothorax (5% subclavian), cardiac perforation, tamponade, infection, wire displacement. Rate set at 60-80 bpm. Threshold check: minimum voltage for consistent capture. Threshold <1V = good position.
Key point
TVP: IJ or subclavian preferred. Fluoroscopy-guided to RV apex. Check pacing threshold <1V. Complications: PTX, perforation.
Question 5 · Permanent pacemaker indications
Correct answer: Symptomatic bradycardia from: complete heart block (permanent), Mobitz II (high progression risk), symptomatic sick sinus syndrome, chronotropic incompetence
Why
PPM indications (NICE/ESC): Complete heart block: always (unless reversible cause). Mobitz II: always (50% risk of progressing to CHB). Sick sinus syndrome with symptoms. Bifascicular/trifascicular block + syncope. NOT: asymptomatic Mobitz I (Wenckebach), isolated bradycardia in athletes. Reversible causes (drug toxicity, inferior MI CHB): treat cause first.
Key point
PPM: CHB always, Mobitz II always (50% CHB risk), symptomatic SSS. Not: asymptomatic Wenckebach or athlete bradycardia.
Question 6 · DCCJ vs pacing
Correct answer: DCCJ delivers a shock to TERMINATE a tachyarrhythmia. It does not create impulses. Bradycardia needs pacing (creates electrical impulses). Atropine for rate increase (blocks vagal)
Why
DCCJ (DC countershock/cardioversion): terminates re-entry tachyarrhythmias by simultaneously depolarising the whole myocardium. Cannot CREATE a new rhythm. Bradycardia (absent/slow impulse formation or conduction failure) requires pacing (artificial electrical stimulus) or atropine (reduces vagal tone, increases SA node rate — only works if AV node intact). DCCJ for bradycardia = no effect.
Key point
DCCJ terminates tachyarrhythmias — cannot create impulses. Bradycardia: pacing (creates stimulus) or atropine (reduces vagal tone).
Case complete