Home › Cases › After They Go Home
Carbon Monoxide Poisoning
After They Go Home
6 questions
Question 1 · The Property
Correct answer: A Gas Safe engineer must clear the property, environmental health must be notified, and CO alarms advised — and check the neighbours
Why
A Gas Safe engineer must clear the property. Notify environmental health. Advise CO alarms. Check neighbours.
- Sending them back to an uncleared property means they are re-exposed, and the next exposure may occur while they are asleep
- Neighbours matter in flats and terraced housing, where a shared flue or an adjoining property can be the source
- Environmental health has powers a clinician does not and can compel action
- Advising the landlord informally is not the same as a formal clearance, and puts the responsibility in the wrong place
Key point
Do not discharge them to an uncleared house. Gas Safe, environmental health, and check the neighbours.
Question 2 · The Delayed Problem
Correct answer: Delayed neuropsychiatric sequelae, occurring 3 to 240 days later — with follow-up arranged
Why
Delayed neuropsychiatric sequelae occur 3 to 240 days after exposure — warn and follow up.
- Features include cognitive impairment, memory problems, personality change, parkinsonism, and mood disturbance — and they can appear weeks after an apparently complete recovery
- The wide window is why follow-up must be arranged, not left to chance
- A patient who develops memory problems two months later will not connect it to a boiler unless they were told
- A normal COHb means the CO has gone; it does not mean no injury occurred — the same distinction as a normal CT after head injury
Key point
Sequelae can appear up to 240 days later. Warn them, or they will never connect it.
Question 3 · Pregnancy
Correct answer: Fetal haemoglobin binds CO avidly, so the fetus is at greater risk — treat longer, and pregnancy is a hyperbaric oxygen criterion
Why
Fetal haemoglobin binds CO avidly — treat longer, and pregnancy is one of the hyperbaric oxygen discussion criteria.
- Fetal COHb rises higher and falls more slowly than maternal, so the mother's level substantially underestimates the fetal exposure — and a normal maternal COHb does not mean the fetus is unaffected
- Treatment duration is therefore extended beyond maternal symptom resolution
- Limiting oxygen out of fetal concern is exactly backwards — the fetus is the reason to treat harder
- Discuss with NPIS, and involve obstetrics
Key point
The mother's level underestimates the fetus. Treat longer, and pregnancy alone is an HBO criterion.
Question 4 · The One With Chest Pain
Correct answer: Myocardial ischaemia from CO — an escalation trigger, and cardiac involvement is a hyperbaric oxygen criterion
Why
Myocardial ischaemia or arrhythmia on ECG or troponin is an escalation trigger, and cardiac involvement is one of the HBO criteria.
- CO reduces oxygen delivery and also binds directly to myoglobin and cytochrome oxidase, impairing cardiac function at tissue level
- It may coexist with underlying coronary disease, and both need addressing — but attributing it entirely to a separate ACS misses the CO contribution and the HBO indication
- Continue high-flow oxygen, and involve cardiology
- Troponin rises in CO poisoning are real and carry adverse prognostic weight
Key point
A troponin rise in CO poisoning is real and is an HBO criterion. Not a coincidental ACS.
Question 5 · When To Stop
Correct answer: When asymptomatic AND COHb is below 3%
Why
Continue until asymptomatic and COHb below 3%. Both conditions.
- Symptoms alone are not enough — a patient can feel better with a substantially raised COHb, and stopping early prolongs the exposure
- The level alone is not enough either, since it falls quickly on oxygen and correlates poorly with severity
- Saturation is meaningless in CO poisoning and will read 100% throughout
- A fixed four-hour rule ignores both the individual half-life and the initial burden
Key point
Asymptomatic AND under 3%. Either alone will stop the oxygen too soon.
Question 6 · The Public Health Job
Correct answer: Ensuring the source is found and made safe, that neighbours are considered, that environmental health is notified, and that CO alarms are advised
Why
The public health job is as important as the clinical one, and it is the part that prevents the next family being poisoned.
- Gas Safe engineer must clear the property; notify environmental health; advise CO alarms; check neighbours
- This mirrors other pathways: notify UKHSA for malaria and typhoid, warn co-travellers — the person in front of you is one of a group
- CO alarms are cheap and effective, and the advice takes ten seconds
- Police involvement is not routine unless there are safeguarding or criminal concerns
- Treating only the patients present leaves the source running
Key point
The boiler is still running. Treating the four in front of you leaves the source in place.
Case complete
Practice on this page does not update your app progress. Open the browser app if you want its learning tools and progress record.