Home › Cases › Carbon Monoxide Poisoning
Deteriorating Patient
Carbon Monoxide Poisoning
6 questions
Question 1 · Recognition
Correct answer: Carbon monoxide poisoning — simultaneous symptoms + malfunctioning gas fire + normal SpO2 (misleading)
Why
CO poisoning: multiple people simultaneously affected in same room, winter (poor ventilation), near combustion source. CRITICAL: SpO2 pulse oximetry is unreliable — haemoglobin saturated with CO reads as oxy-haemoglobin, giving falsely normal reading.
Key point
CO: simultaneous symptoms in family + combustion source. SpO2 falsely normal — unreliable.
Question 2 · Immediate treatment
Correct answer: 100% O2 via non-rebreather mask, remove from exposure, contact Hyperbaric centre if: loss of consciousness, neurological features, COHb >25%, pregnancy, cardiac features
Why
CO treatment: immediate 100% O2 via NRB reduces CO-Hb half-life from 5h to 60-90 min. Remove from source. Hyperbaric O2 indications:
- LOC (any duration)
- Neurological symptoms
- COHb >25%
- Pregnancy (even at lower levels)
- Cardiac arrhythmia or ischaemia
Key point
100% O2 via NRB immediately. Consider hyperbaric O2 for LOC, neuro features, COHb >25%, pregnancy.
Question 3 · Confirming diagnosis
Correct answer: ABG on co-oximeter (direct COHb measurement). Standard ABG may show normal pO2 — only co-oximeter measures COHb
Why
CO diagnosis: ABG co-oximeter is gold standard — directly measures carboxyhaemoglobin (COHb) percentage. Standard ABG shows pO2 (dissolved O2) which may be normal or elevated. Pulse oximetry unreliable (COHb reads as oxyHb). Request 'co-oximetry' when sending ABG.
Key point
CO confirmed by ABG co-oximeter only. Standard ABG pO2 can be NORMAL in severe CO poisoning.
Question 4 · Neurological sequelae
Correct answer: Delayed neurological syndrome (DNS) — occurs in 10-30% of moderate-severe CO poisoning, 2-4 weeks after apparent recovery
Why
Delayed neurological syndrome (DNS): cognitive impairment, personality change, parkinsonism, apraxia, urinary incontinence — appearing 2-4 weeks after apparent CO recovery. Affects 10-30% after severe poisoning. Hypothesised to relate to demyelination from oxidative injury. Some recover, some don't.
Key point
DNS: cognitive/personality change 2-4 weeks after severe CO. Warn patients. Neuropsychiatry follow-up.
Question 5 · Source investigation
Correct answer: Gas engineer/Fire Brigade inspection of appliances before re-entry. Carbon monoxide detector installation
Why
Before returning home:
- Gas Safe registered engineer to inspect and repair faulty appliance
- Fire Brigade investigation if needed
- CO detector installation (fitting detectors is not same as replacing faulty boiler — source must be identified and fixed)
- Social care involvement if vulnerable
Key point
Faulty appliance must be inspected and repaired before re-entry. CO detector fitting — but must fix source.
Question 6 · Mandatory reporting
Correct answer: Unexpected CO deaths reported to coroner. Occupational exposure: RIDDOR. Gas appliance fault: Gas Emergency Service (National Gas Emergency number 0800 111 999)
Why
CO poisoning reporting:
- Unexpected death = coroner
- Occupational CO exposure = RIDDOR reporting
- Faulty gas appliance = Gas Emergency Service 0800 111 999 (24h)
- Carbon monoxide is notifiable in some jurisdictions
- HSE involvement if occupational
Key point
CO death: coroner. Faulty appliance: Gas Emergency Service 0800 111 999. Occupational: RIDDOR.
Case complete
Practice on this page does not update your app progress. Open the browser app if you want its learning tools and progress record.